Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 18.472
1.
Medicine (Baltimore) ; 103(19): e38089, 2024 May 10.
Article En | MEDLINE | ID: mdl-38728501

Proton beam therapy (PBT) has great advantages as tumor radiotherapy and is progressively becoming a more prevalent choice for individuals undergoing radiation therapy. The objective of this review is to pinpoint collaborative efforts among countries and institutions, while also exploring the hot topics and future outlook in the field of PBT. Data from publications were downloaded from the Web of Science Core Collection. CiteSpace and Excel 2016 were used to conduct the bibliometric and knowledge map analysis. A total of 6516 publications were identified, with the total number of articles steadily increasing and the United States being the most productive country. Harvard University took the lead in contributing the highest number of publications. Paganetti Harald published the most articles and had the most cocitations. PHYS MED BIOL published the greatest number of PBT-related articles, while INT J RADIAT ONCOL received the most citations. Paganetti Harald, 2012, PHYS MED BIOL can be classified as classic literature due to its high citation rate. We believe that research on technology development, dose calculation and relative biological effectiveness were the knowledge bases in this field. Future research hotspots may include clinical trials, flash radiotherapy, and immunotherapy.


Bibliometrics , Proton Therapy , Proton Therapy/statistics & numerical data , Proton Therapy/methods , Humans , Biomedical Research/statistics & numerical data , Neoplasms/radiotherapy
2.
Sci Rep ; 14(1): 10637, 2024 05 09.
Article En | MEDLINE | ID: mdl-38724569

Hadron therapy is an advanced radiation modality for treating cancer, which currently uses protons and carbon ions. Hadrons allow for a highly conformal dose distribution to the tumour, minimising the detrimental side-effects due to radiation received by healthy tissues. Treatment with hadrons requires sub-millimetre spatial resolution and high dosimetric accuracy. This paper discusses the design, fabrication and performance tests of a detector based on Gas Electron Multipliers (GEM) coupled to a matrix of thin-film transistors (TFT), with an active area of 60 × 80 mm2 and 200 ppi resolution. The experimental results show that this novel detector is able to detect low-energy (40 kVp X-rays), high-energy (6 MeV) photons used in conventional radiation therapy and protons and carbon ions of clinical energies used in hadron therapy. The GEM-TFT is a compact, fully scalable, radiation-hard detector that measures secondary electrons produced by the GEMs with sub-millimetre spatial resolution and a linear response for proton currents from 18 pA to 0.7 nA. Correcting known detector defects may aid in future studies on dose uniformity, LET dependence, and different gas mixture evaluation, improving the accuracy of QA in radiotherapy.


Radiometry , Radiometry/instrumentation , Radiometry/methods , Humans , Radiotherapy/methods , Radiotherapy/standards , Radiotherapy/instrumentation , Quality Assurance, Health Care , Electrons , Radiotherapy Dosage , Neoplasms/radiotherapy , Equipment Design , Proton Therapy/instrumentation , Proton Therapy/methods
5.
Nano Lett ; 24(19): 5894-5903, 2024 May 15.
Article En | MEDLINE | ID: mdl-38709593

The combination of radiotherapy (RT) and immunotherapy shows promise in improving the clinical treatment of solid tumors; however, it faces challenges of low response rates and systemic toxicity. Herein, an implantable alginate/collagen hydrogel encapsulating C-C motif ligand 21 (CCL21)-expressing dendritic cells (CCL21-DCs@gel) was developed to potentiate the systemic antitumor effects of RT. The hydrogel functioned as a suitable reservoir for in vivo culture and proliferation of CCL21-DCs, thereby enabling sustained CCL21 release. The local CCL21 gradient induced by CCL21-DCs@gel significantly enhanced the efficacy of RT in suppressing primary tumor growth and inhibiting distant metastasis across several mouse models. Furthermore, the combination of RT with CCL21-DCs@gel provided complete prophylactic protection to mice. Mechanistic investigations revealed that CCL21-DCs@gel potentiated RT by promoting tumor lymphangiogenesis and attracting immune cell infiltration into the tumor. Collectively, these results suggest that CCL21-DCs@gel is a promising adjunct to RT for effectively eradicating tumors and preventing tumor recurrence.


Chemokine CCL21 , Dendritic Cells , Hydrogels , Animals , Hydrogels/chemistry , Mice , Dendritic Cells/drug effects , Dendritic Cells/immunology , Cell Line, Tumor , Humans , Alginates/chemistry , Neoplasms/radiotherapy , Neoplasms/pathology , Neoplasms/immunology , Collagen/chemistry , Immunotherapy/methods
6.
J Nucl Med ; 65(Suppl 1): 4S-11S, 2024 May 06.
Article En | MEDLINE | ID: mdl-38719234

Quinoline-based fibroblast activation protein (FAP) inhibitors (FAPIs) have recently emerged as a focal point in global nuclear medicine, underscored by their promising applications in cancer theranostics and the diagnosis of various nononcological conditions. This review offers an in-depth summary of the existing literature on the evolution and use of FAPI tracers in China, tracing their journey from preclinical to clinical research. Moreover, this review also assesses the diagnostic accuracy of FAPI PET for the most common cancers in China, analyzes its impact on oncologic management paradigms, and investigates the potential of FAP-targeted radionuclide therapy in patients with advanced or metastatic cancer. This review also summarizes studies using FAPI PET for nononcologic disorders in China. Thus, this qualitative overview presents a snapshot of China's engagement with FAPI tracers, aiming to guide future research endeavors.


Endopeptidases , Gelatinases , Membrane Proteins , Serine Endopeptidases , Translational Research, Biomedical , Humans , China , Membrane Proteins/antagonists & inhibitors , Membrane Proteins/metabolism , Gelatinases/antagonists & inhibitors , Gelatinases/metabolism , Serine Endopeptidases/metabolism , Radioactive Tracers , Animals , Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Positron-Emission Tomography
7.
J Nucl Med ; 65(Suppl 1): 38S-45S, 2024 May 06.
Article En | MEDLINE | ID: mdl-38719241

Radiopharmaceuticals play a critical role in nuclear medicine, providing novel tools for specifically delivering radioisotopes for the diagnosis and treatment of cancers. As the starting point for developing radiopharmaceuticals, cancer-specific biomarkers are important and receive worldwide attention. This field in China is currently experiencing a rapid expansion, with multiple radiotracers targeting novel targets being developed and translated into clinical studies. This review provides a brief overview of the exploration of novel imaging targets, preclinical evaluation of their targeting ligands, and translational research in China from 2020 to 2023, for detecting cancer, guiding targeted therapy, and visualizing the immune microenvironment. We believe that China will play an even more important role in the development of nuclear medicine in the world in the future.


Biomarkers, Tumor , Neoplasms , Radioactive Tracers , Humans , China , Biomarkers, Tumor/metabolism , Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Radiopharmaceuticals , Animals
8.
Chin Clin Oncol ; 13(2): 24, 2024 Apr.
Article En | MEDLINE | ID: mdl-38711177

BACKGROUND AND OBJECTIVE: Positron emission tomography (PET) imaging has been useful in delineating tumor volumes and allowing for improved radiation treatment. The field of PET-guided radiotherapy is rapidly growing and will have significant impact on radiotherapy delivery in the future. This narrative review provides an overview of the current state of PET-guided radiotherapy as well as the future directions of the field. METHODS: For this narrative review, PubMed was searched for articles from 2010-2023. A total of 18 keywords or phrases were searched to provide an overview of PET-guided radiotherapy, radiotracers, the role of PET-guided radiotherapy in oligometastatic disease, and biology-guided radiotherapy (BgRT). The first 300 results for each keyword were searched and relevant articles were extracted. The references of these articles were also reviewed for relevant articles. KEY CONTENT AND FINDINGS: In radiotherapy, 18F-2-fluoro-2-deoxy-D-glucose (F-FDG or FDG) is the major radiotracer for PET and when combined with computed tomography (CT) scan allows for anatomic visualization of metabolically active malignancy. Novel radiotracers are being explored to delineate certain cell types and numerous tumor metrics including metabolism, hypoxia, vascularity, and cellular proliferation. This molecular and functional imaging will provide improved tumor characterization. Through these radiotracers, radiation plans can employ dose painting by creating different dose levels based upon specific risk factors of the target volume. Additionally, biologic imaging during radiotherapy can allow for adaptation of the radiation plan based on response to treatment. Dose painting and adaptive radiotherapy should improve the therapeutic ratio through more selective dose delivery. The novel PET-linear accelerator hopes to combine these techniques and more by using radiotracers to deliver BgRT. The areas of radiotracer uptake will serve as fiducials to guide radiotherapy to themselves. This technique may prove promising in the growing area of oligometastatic radiation treatment. CONCLUSIONS: Significant challenges exist for the future of PET-guided radiotherapy. However, with the advancements being made, PET imaging is set to change the delivery of radiotherapy.


Positron-Emission Tomography , Radiotherapy, Image-Guided , Humans , Positron-Emission Tomography/methods , Radiotherapy, Image-Guided/methods , Neoplasms/radiotherapy , Neoplasms/diagnostic imaging
9.
JCO Glob Oncol ; 10: e2300462, 2024 May.
Article En | MEDLINE | ID: mdl-38723217

PURPOSE: Radiation oncology in the Philippines, a large lower- and middle-income country in Southeast Asia, is facing a critical shortage in manpower, with only 113 radiation oncologists (ROs) over 55 radiotherapy (RT) centers serving 100 million population. Paramount to workforce expansion is ensuring that training programs can produce adequately trained specialists. In this study, we describe the current state of radiation oncology training programs in the Philippines. METHODS: This is a cross-sectional observational analysis of the nine radiation oncology residency training programs in the Philippines. Data were collected from a survey of the program directors, the Philippine Radiation Oncology Society database, and a PubMed literature search. RESULTS: Eight of the nine programs are in the National Capital Region. Since program standardization in 2005, there have been 82 four-year residency graduates, with up to 18 new graduates annually. Faculty-to-trainee ratio ranges from 0.5 to 2.67. In terms of technology, all programs have intensity-modulated RT and high-dose-rate brachytherapy, but only six are equipped with computed tomography-based image guidance and stereotactic capabilities. Clinical education schemes vary per institution regarding curriculum implementation, resident activities, and methods of evaluation. Required resident case logs are not met for lung, GI, genitourinary, bone and soft tissue, and hematologic malignancies. In total, there are only 22 resident-led publications from 10 unique individuals in two training programs. CONCLUSION: Program expansions are warranted to meet the projected demand for ROs in the Philippines, but training programs must first improve key aspects of staffing, technology, clinical education, and research. Addressing training challenges related to resource limitations necessitates local and international collaborations with higher-capacity centers to bridge gaps for continued quality improvement with the aim of ultimately delivering better overall cancer care.


Developing Countries , Radiation Oncology , Philippines , Humans , Radiation Oncology/education , Cross-Sectional Studies , Neoplasms/radiotherapy , Internship and Residency/statistics & numerical data
10.
JAMA Netw Open ; 7(5): e2410819, 2024 May 01.
Article En | MEDLINE | ID: mdl-38691356

Importance: In 2018, the first online adaptive magnetic resonance (MR)-guided radiotherapy (MRgRT) system using a 1.5-T MR-equipped linear accelerator (1.5-T MR-Linac) was clinically introduced. This system enables online adaptive radiotherapy, in which the radiation plan is adapted to size and shape changes of targets at each treatment session based on daily MR-visualized anatomy. Objective: To evaluate safety, tolerability, and technical feasibility of treatment with a 1.5-T MR-Linac, specifically focusing on the subset of patients treated with an online adaptive strategy (ie, the adapt-to-shape [ATS] approach). Design, Setting, and Participants: This cohort study included adults with solid tumors treated with a 1.5-T MR-Linac enrolled in Multi Outcome Evaluation for Radiation Therapy Using the MR-Linac (MOMENTUM), a large prospective international study of MRgRT between February 2019 and October 2021. Included were adults with solid tumors treated with a 1.5-T MR-Linac. Data were collected in Canada, Denmark, The Netherlands, United Kingdom, and the US. Data were analyzed in August 2023. Exposure: All patients underwent MRgRT using a 1.5-T MR-Linac. Radiation prescriptions were consistent with institutional standards of care. Main Outcomes and Measures: Patterns of care, tolerability, and technical feasibility (ie, treatment completed as planned). Acute high-grade radiotherapy-related toxic effects (ie, grade 3 or higher toxic effects according to Common Terminology Criteria for Adverse Events version 5.0) occurring within the first 3 months after treatment delivery. Results: In total, 1793 treatment courses (1772 patients) were included (median patient age, 69 years [range, 22-91 years]; 1384 male [77.2%]). Among 41 different treatment sites, common sites were prostate (745 [41.6%]), metastatic lymph nodes (233 [13.0%]), and brain (189 [10.5%]). ATS was used in 1050 courses (58.6%). MRgRT was completed as planned in 1720 treatment courses (95.9%). Patient withdrawal caused 5 patients (0.3%) to discontinue treatment. The incidence of radiotherapy-related grade 3 toxic effects was 1.4% (95% CI, 0.9%-2.0%) in the entire cohort and 0.4% (95% CI, 0.1%-1.0%) in the subset of patients treated with ATS. There were no radiotherapy-related grade 4 or 5 toxic effects. Conclusions and Relevance: In this cohort study of patients treated on a 1.5-T MR-Linac, radiotherapy was safe and well tolerated. Online adaptation of the radiation plan at each treatment session to account for anatomic variations was associated with a low risk of acute grade 3 toxic effects.


Neoplasms , Radiotherapy, Image-Guided , Humans , Radiotherapy, Image-Guided/methods , Radiotherapy, Image-Guided/adverse effects , Male , Female , Middle Aged , Aged , Neoplasms/radiotherapy , Neoplasms/diagnostic imaging , Adult , Prospective Studies , Magnetic Resonance Imaging/methods , Feasibility Studies , Cohort Studies , Aged, 80 and over
11.
Front Immunol ; 15: 1358478, 2024.
Article En | MEDLINE | ID: mdl-38698840

Introduction: Cancer combination treatments involving immunotherapies with targeted radiation therapy are at the forefront of treating cancers. However, dosing and scheduling of these therapies pose a challenge. Mathematical models provide a unique way of optimizing these therapies. Methods: Using a preclinical model of multiple myeloma as an example, we demonstrate the capability of a mathematical model to combine these therapies to achieve maximum response, defined as delay in tumor growth. Data from mice studies with targeted radionuclide therapy (TRT) and chimeric antigen receptor (CAR)-T cell monotherapies and combinations with different intervals between them was used to calibrate mathematical model parameters. The dependence of progression-free survival (PFS), overall survival (OS), and the time to minimum tumor burden on dosing and scheduling was evaluated. Different dosing and scheduling schemes were evaluated to maximize the PFS and optimize timings of TRT and CAR-T cell therapies. Results: Therapy intervals that were too close or too far apart are shown to be detrimental to the therapeutic efficacy, as TRT too close to CAR-T cell therapy results in radiation related CAR-T cell killing while the therapies being too far apart result in tumor regrowth, negatively impacting tumor control and survival. We show that splitting a dose of TRT or CAR-T cells when administered in combination is advantageous only if the first therapy delivered can produce a significant benefit as a monotherapy. Discussion: Mathematical models are crucial tools for optimizing the delivery of cancer combination therapy regimens with application along the lines of achieving cure, maximizing survival or minimizing toxicity.


Immunotherapy, Adoptive , Receptors, Chimeric Antigen , Animals , Immunotherapy, Adoptive/methods , Mice , Combined Modality Therapy/methods , Receptors, Chimeric Antigen/immunology , Humans , Multiple Myeloma/therapy , Multiple Myeloma/immunology , Multiple Myeloma/radiotherapy , Models, Theoretical , Cell Line, Tumor , Neoplasms/therapy , Neoplasms/immunology , Neoplasms/radiotherapy , Radioisotopes/therapeutic use , T-Lymphocytes/immunology , Xenograft Model Antitumor Assays
12.
J Cancer Res Clin Oncol ; 150(5): 226, 2024 May 02.
Article En | MEDLINE | ID: mdl-38696003

High-linear energy transfer (LET) radiation is a promising alternative to conventional low-LET radiation for therapeutic gain against cancer owing to its ability to induce complex and clustered DNA lesions. However, the development of radiation resistance poses a significant barrier. The potential molecular mechanisms that could confer resistance development are translesion synthesis (TLS), replication gap suppression (RGS) mechanisms, autophagy, epithelial-mesenchymal transition (EMT) activation, release of exosomes, and epigenetic changes. This article will discuss various types of complex clustered DNA damage, their repair mechanisms, mutagenic potential, and the development of radiation resistance strategies. Furthermore, it highlights the importance of careful consideration and patient selection when employing high-LET radiotherapy in clinical settings.


Linear Energy Transfer , Neoplasms , Radiation Tolerance , Humans , Neoplasms/radiotherapy , Neoplasms/pathology , DNA Damage/radiation effects , DNA Repair/radiation effects , Animals
13.
BMC Cancer ; 24(1): 556, 2024 May 03.
Article En | MEDLINE | ID: mdl-38702617

Radiotherapy is a mainstay of cancer treatment. The clinical response to radiotherapy is heterogeneous, from a complete response to early progression. Recent studies have explored the importance of patient characteristics in response to radiotherapy. In this editorial, we invite contributions for a BMC Cancer collection of articles titled 'Advances in personalized radiotherapy' towards the improvement of treatment response.


Neoplasms , Precision Medicine , Humans , Precision Medicine/methods , Neoplasms/radiotherapy , Radiotherapy/methods , Radiotherapy/trends , Treatment Outcome
14.
Nutrients ; 16(9)2024 Apr 30.
Article En | MEDLINE | ID: mdl-38732610

Oncological patients show intense catabolic activity, as well as a susceptibility to higher nutritional risk and clinical complications. Thus, tools are used for monitoring prognosis. Our objective was to analyze the nutrition prognosis of patients who underwent radiotherapy, correlating it with outcomes and complications. We performed a retrospective transversal study based on secondary data from hospital records of patients who started radiotherapy between July 2022 and July 2023. We established Prognostic Scores through a combination of Prognostic Nutritional Index (PNI) and a Subjective Global Assessment (SGA), assessed at the beginning and end of treatment. Score 3 patients, with PNI ≤ 45.56 and an SGA outcome of malnutrition, initially presented a higher occurrence of odynophagia, later also being indicative of reduced diet volume, treatment interruption, and dysphagia. SGA alone showed sensitivity to altered diet volume, dysphagia, and xerostomia in the second assessment. Besides this, PNI ≤ 45.56 also indicated the use of alternative feeding routes, treatment interruption, and hospital discharge with more complications. We conclude that the scores could be used to indicate complications; however, further studies on combined biomarkers are necessary.


Malnutrition , Nutrition Assessment , Nutritional Status , Humans , Male , Female , Retrospective Studies , Middle Aged , Prognosis , Aged , Malnutrition/etiology , Malnutrition/diagnosis , Deglutition Disorders/etiology , Neoplasms/radiotherapy , Radiotherapy/adverse effects , Cross-Sectional Studies , Adult
15.
J Appl Clin Med Phys ; 25(5): e14344, 2024 May.
Article En | MEDLINE | ID: mdl-38615273

PURPOSE: Radiotherapy (RT) treatment and treatment planning is a complex process prepared and delivered by a multidisciplinary team of specialists. Efficient communication and notification systems among different team members are therefore essential to ensure the safe, timely delivery of treatments to patients. METHOD: To address this issue, we developed and implemented automated notification systems and an electronic whiteboard to track every CT simulation, contouring task, the new-start schedule, and physician's appointments and tasks, and notify team members of overdue and missing tasks and appointments. The electronic whiteboard was developed to have a straightforward view of current patients' planning workflow and to help different team members coordinate with each other. The systems were implemented and have been used at our center to monitor the progress of treatment-planning tasks for over 2 years. RESULTS: The last-minute plans were relatively reduced by about 40% in 2023 compared to 2021 and 2022 with a p-value < 0.05. The overdue contouring tasks of more than 1 day decreased from 46.8% in 2019 and 33.6% in 2020 to 20%-26.4% in 2021-2023 with a p-value < 0.05 after the implementation of the notification system. The rate of plans with 1-3 day planning time decreased by 20.31%, 39.32%, and 24.08% with a p-value < 0.05 and the rate of plans with 1-3 day planning time due to the contouring task overdue more than 1 day decreased by 49.49%, 56.89%, and 46.52% with a p-value < 0.05 after the implementation. The rate of outstanding appointments that are overdue by more than 7 days decreased by more than 5% with a p-value < 0.05 following the implementation of the system. CONCLUSIONS: Our experience shows that this system requires minimal human intervention, improves the treatment planning workflow and process by reducing errors and delays in the treatment planning process, positively impacts on-time treatment plan completion, and reduces the need for compressed or rushed treatment planning timelines.


Neoplasms , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Radiotherapy Planning, Computer-Assisted/methods , Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Workflow , Tomography, X-Ray Computed/methods
16.
J Appl Clin Med Phys ; 25(5): e14357, 2024 May.
Article En | MEDLINE | ID: mdl-38620027

PURPOSE: To investigate and characterize the performance of a novel orthogonal dual-layer alpha multileaf collimator (αMLC) mounted on the LinaTech VenusX linac. METHODS: We evaluated leaf positioning accuracy and reproducibility using an electronic portal imaging device through the picket fence test. The average, interleaf, intraleaf, and leaf tip transmissions of the single and dual layers were measured using an ionization chamber. Square and rhombus fields were used to evaluate the leaf penumbra of αMLC. To investigate the advantages of the orthogonal dual-layer multileaf collimator (MLC) in field shaping, right triangular and circular pattern fields were formed using both the dual layers and single layers of the αMLC. RESULTS: The average maximum positioning deviations of the upper and lower αMLC over 1 year were 0.76 ± 0.09 mm and 0.62 ± 0.07 mm, respectively. The average transmissions were 1.87%, 1.83%, and 0.03% for the upper-, lower- and dual-layer αMLC, respectively. The maximum interleaf transmissions of the lower- and dual-layer were 2.43% and 0.17%, respectively. The leaf tip transmissions were 9.34% and 0.25%, respectively. The penumbra of the square field was 6.2 mm in the X direction and 8.0 mm in the Y direction. The average penumbras of the rhombus fields with side lengths of 5 and 10 cm were 3.6 and 4.9 mm, respectively. For the right triangular and circular fields, the fields shaped by the dual-layer leaves were much closer to the set field than those shaped by single-layer leaves. The dose undulation amplitude of the 50% isodose lines and leaf stepping angle change of the dual-layer leaves were smaller than those of the single-layer leaves. CONCLUSIONS: The αMLC benefits from its orthogonal dual-layer design. Leaf transmission, dose undulations at the field edge, and MLC field dependence of the leaf stepping angle of the dual-layer αMLC were remarkably reduced.


Particle Accelerators , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Particle Accelerators/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Neoplasms/radiotherapy , Phantoms, Imaging
17.
J Appl Clin Med Phys ; 25(5): e14336, 2024 May.
Article En | MEDLINE | ID: mdl-38664983

PURPOSE: Ring and tandem (R&T) applicator digitization is currently performed at our institution by manually defining the extent of the applicators. Digitization can also be achieved using solid applicators: predefined, 3D models with geometric constraints. This study compares R&T digitization using manual and solid applicator methods through Failure Modes and Effects Analyses (FMEAs) and comparative time studies. We aim to assess the suitability of solid applicator method implementation for R&T cases METHODS: Six qualified medical physicists (QMPs) and two medical physics residents scored potential modes of failure of manual digitization in an FMEA as recommended by TG-100. Occurrence, severity, and detectability (OSD) values were averaged across respondents and then multiplied to form combined Risk Priority Numbers (RPNs) for analysis. Participants were trained to perform treatment planning using a developed solid applicator protocol and asked to score a second FMEA on the distinct process steps from the manual method. For both methods, participant digitization was timed. FMEA and time data were analyzed across methods and participant samples RESULTS: QMPs rated the RPNs of the current, manual method of digitization statistically lower than residents did. When comparing the unique FMEA steps between the two digitization methods, QMP respondents found no significant difference in RPN means. Residents, however, rated the solid applicator method as higher risk. Further, after the solid applicator method was performed twice by participants, the time to digitize plans was not significantly different from manual digitization CONCLUSIONS: This study indicates the non-inferiority of the solid applicator method to manual digitization in terms of risk, according to QMPs, and time, across all participants. Differences were found in FMEA evaluation and solid applicator technique adoption based on years of brachytherapy experience. Further practice with the solid applicator protocol is recommended because familiarity is expected to lower FMEA occurrence ratings and further reduce digitization times.


Brachytherapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Brachytherapy/methods , Brachytherapy/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Healthcare Failure Mode and Effect Analysis , Neoplasms/radiotherapy
18.
J Appl Clin Med Phys ; 25(5): e14366, 2024 May.
Article En | MEDLINE | ID: mdl-38669190

PURPOSE: Skin collimation is a useful tool in electron beam therapy (EBT) to decrease the penumbra at the field edge and minimize dose to nearby superficial organs at risk (OARs), but manually fabricating these collimation devices in the clinic to conform to the patient's anatomy can be a difficult and time intensive process. This work compares two types of patient-specific skin collimation (in-house 3D printed and vendor-provided machined brass) using clinically relevant metrics. METHODS: Attenuation measurements were performed to determine the thickness of each material needed to adequately shield both 6 and 9 MeV electron beams. Relative and absolute dose planes at various depths were measured using radiochromic film to compare the surface dose, flatness, and penumbra of the different skin collimation materials. RESULTS: Clinically acceptable thicknesses of each material were determined for both 6 and 9 MeV electron beams. Field width, flatness, and penumbra results between the two systems were very similar and significantly improved compared to measurements performed with no surface collimation. CONCLUSION: Both skin collimation methods investigated in this work generate sharp penumbras at the field edge and can minimize dose to superficial OARs compared to treatment fields with no surface collimation. The benefits of skin collimation are greatest for lower energy electron beams, and the benefits decrease as the measurement depth increases. Using bolus with skin collimation is recommended to avoid surface dose enhancement seen with collimators placed on the skin surface. Ultimately, the appropriate choice of material will depend on the desire to create these devices in-house or outsource the fabrication to a vendor.


Electrons , Organs at Risk , Printing, Three-Dimensional , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Skin , Humans , Electrons/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Skin/radiation effects , Phantoms, Imaging , Neoplasms/radiotherapy , Particle Accelerators/instrumentation
19.
Br J Cancer ; 130(10): 1621-1634, 2024 Jun.
Article En | MEDLINE | ID: mdl-38575732

BACKGROUND: DNA double-strand break (DSB) induction and repair are important events for determining cell survival and the outcome of cancer radiotherapy. The DNA-dependent protein kinase (DNA-PK) complex functions at the apex of DSBs repair, and its assembly and activity are strictly regulated by post-translation modifications (PTMs)-associated interactions. However, the PTMs of the catalytic subunit DNA-PKcs and how they affect DNA-PKcs's functions are not fully understood. METHODS: Mass spectrometry analyses were performed to identify the crotonylation sites of DNA-PKcs in response to γ-ray irradiation. Co-immunoprecipitation (Co-IP), western blotting, in vitro crotonylation assays, laser microirradiation assays, in vitro DNA binding assays, in vitro DNA-PK assembly assays and IF assays were employed to confirm the crotonylation, identify the crotonylase and decrotonylase, and elucidate how crotonylation regulates the activity and function of DNA-PKcs. Subcutaneous xenografts of human HeLa GCN5 WT or HeLa GCN5 siRNA cells in BALB/c nude mice were generated and utilized to assess tumor proliferation in vivo after radiotherapy. RESULTS: Here, we reveal that K525 is an important site of DNA-PKcs for crotonylation, and whose level is sharply increased by irradiation. The histone acetyltransferase GCN5 functions as the crotonylase for K525-Kcr, while HDAC3 serves as its dedicated decrotonylase. K525 crotonylation enhances DNA binding activity of DNA-PKcs, and facilitates assembly of the DNA-PK complex. Furthermore, GCN5-mediated K525 crotonylation is indispensable for DNA-PKcs autophosphorylation and the repair of double-strand breaks in the NHEJ pathway. GCN5 suppression significantly sensitizes xenograft tumors of mice to radiotherapy. CONCLUSIONS: Our study defines K525 crotonylation of DNA-PKcs is important for the DNA-PK complex assembly and DSBs repair activity via NHEJ pathway. Targeting GCN5-mediated K525 Kcr of DNA-PKcs may be a promising therapeutic strategy for improving the outcome of cancer radiotherapy.


DNA Breaks, Double-Stranded , DNA Repair , DNA-Activated Protein Kinase , Mice, Inbred BALB C , Radiation Tolerance , p300-CBP Transcription Factors , Humans , Animals , DNA-Activated Protein Kinase/metabolism , Mice , p300-CBP Transcription Factors/metabolism , HeLa Cells , Mice, Nude , Female , Protein Processing, Post-Translational , Neoplasms/radiotherapy , Neoplasms/metabolism , Neoplasms/genetics , Xenograft Model Antitumor Assays
20.
Br J Cancer ; 130(10): 1593-1598, 2024 Jun.
Article En | MEDLINE | ID: mdl-38615107

Here, we report on the process of a highly impactful and successful creative, collaborative, and multi-partner public engagement project, Radiation Reveal. It brought together ten young adults aged 17-25-year-olds with experience of radiotherapy with researchers at Cancer Research UK RadNet City of London across three 2-hour online workshops. Our aims were to 1) initiate discussions between young adults and radiation researchers, and 2) identify what people wish they had known about radiotherapy before or during treatment. These aims were surpassed; other benefits included peer support, participants' continued involvement in subsequent engagement projects, lasting friendships, creation of support groups for others, and creation and national dissemination of top ten tips for medical professionals and social media resources. A key learning was that this project required a dedicated and (com)passionate person with connections to national cancer charities. When designing the project, constant feedback is also needed from charities and young adults with and without radiotherapy experience. Finally, visually capturing discussions and keeping the door open beyond workshops further enhanced impact. Here, we hope to inform and inspire people to help project the patient voice in all we do.


Neoplasms , Humans , Young Adult , Adult , Adolescent , Female , Male , Neoplasms/radiotherapy , Biomedical Research
...